Stilsoft
Integrated Security Solutions
(495) 663-71-75
Solutions
Special Solutions include state-of-art systems and products intended for intelligent surveillance and security of large open spaces, state borders, long perimeters, standalone systems.
Safe City systems provide complex approach to secure sensitive city infrastructure. Stilsoft profound security expertise, supported by its technological know-how, integration expertise and innovative approach ensure high efficiency of any Safe City project.
Stilsoft has developed an integrated security system called Stilsoft Complex designed to ensure safety of any site. Stilsoft Complex includes the following subsystems: data collection and processing system, access control system, fire and burglar alarm system, public addressing system, command and control system and many more.
Stilsoft develops unmanned aerial vehicles (drones) to secure perimeters, state borders, for search and rescue missions, accident surveillance.
Products and Technologies
Mobile Communication System
“Unicom-1” mobile communication system is intended for control of border guards patrol duties
Long-Range Video Surveillance System
“Stilsoft Observer” standalone long-range video surveillance and thermal imaging system is intended for protection and surveillance of state boarders, big open spaces and remote sites.
Face Recognition Technology
Face recognition technology developed by Stilsoft allows creation of automated access points at sensitive and military infrastructures and search for wanted persons for security forces and agencies.
News
Stilsoft GC continues to certificate the conformity of own-produced transport security systems in accordance to its functionalities. A new certificate № MIA RF.03.000243 has been accepted to surveillance systems of the line of products, such as video cameras, floodlights, server cabinets, controllers and other related equipment. In accordance to the Federal Law № 9 of February 2007 the goals of p...
Published: 16.04.2019
Engineers from Stilsoft GC have developed a new bispectral device, designed for 24/7 video surveillance in infrared and visual range. Structurally, DVS-3675 incorporates classical video camera and thermal imaging camera into one sealed housing with high Ingress Protection. It is also equipped with heating. DVS-3675 module demonstrates excellent quality of video control at any level of illuminati...
Published: 02.04.2019

CVD-123 Security Sensor

Purpose

CVD-123 infrared security sensor is applied to detects changes in infrared range caused by intruders moving through the detection pattern.

Consists of separate transmitter and receiver.

CVD-123 - Digital twin beams detector incorporated in plastic case. Enables lens alignment angle at ±10° (vertical) and ±90° (horizontal). Internal heating ensures flawless operation in temperatures from -40 to +50°C.

CVD-123 outputs an alarm when the infrared pulse beam emitted from its transmitter is not received by the receiver for a certain period of time.

CVD-123 can be mounted on a pole and on fencing.

CVD-123 consists of:

- transmitter – 1 pc.;

- receiver – 1 pc.

- mounting kit – 1 set

Receiver and transmitter are placed facing each other at the opposite sides if protected area. Transmitter emits IR beams heading receiver. Movement within the detection zone between receiver and transmitter triggers alarm. Receiver transmits alarm to controller by means of wired communication. Controller then forwards information to data collection and processing system.

Application.

CVD-123 can operate independently or as a part of perimeter security systems.

Parameter Value
Detection area length, m 1-100
Number of synchronized IR beams, pcs. 2
Number of operating IR channels, pcs. 4
DC voltage, V from 10 to 30
Max input current @ 12V voltage, mA: - receiver - transmitter 80 20
Heater consumed current @12V, A 0,15
Adjustable beam response time, ms from 50 to 700
Item sensitivity to AC powered lighting devices, lx 2000
Item sensitivity to solar light and DC powered lighting devices, Lx 30000
Optical signal depreciation factor (at max range), not less 100
Max optical loss (at max range), % 99
Wave length, over, nm 760
Alarm generation at open output circuit contacts Yes
Informativity 3
Sensor warm-up time, s 45
Efficient illumination width, cm 20
Alarm duration time, not less: – ms; – s 50 2
Recovery time, not more, s 10
Tamper switch Да
Beam alignment angle, vertical, not less, ° ±10
Beam alignment angle, horizontal, not less, ° ±90
Alarm and Power LED Yes
7-segment signal indicator Yes
Signal voltage control Yes
Operating mode Continuous
Unit interchangeability Yes
Mean time between false alarms, h 1200
Mean time between failures alarms, h 60000
Operating temperatures, °С from –40 to +70
Overall dimensions of each unit, mm 170х81х78
Weight, kg 1