Uninterruptible power supply system Energet 1
ENERGET 1 uninterruptible power supply system is designed to provide stabilized voltage of three-phase AC network at 380V and ensure backup power supply in case of main power line failure.

PURPOSE

ENERGET 1 uninterruptible power supply system is designed to provide stabilized voltage of three-phase AC network at 380V and ensure backup power supply in case of main power line failure.

FIELDS OF APPLICATION

  • objects classified as first category of power supply reliability
  • objects requiring autonomous power supply, including those located in regions with unfavorable climatic conditions

VERSION

  • the system is enclosed in a thermally insulated metal container which houses a diesel generator, an uninterruptible power supply source, and a controller
  • the container is equipped with a self-safety system, access control and management system, security and fire alarm system, automatic fire extinguishing system, heating and ventilation systems, and protective grounding

FEATURES

  • automatic switching to backup power supply from the diesel generator in case of main line failure
  • maintenance of equipment power supply from the uninterruptible power supply source during the period between main line failure and full launch of the diesel generator
  • power supply from the backup source for any type of energy consumer
  • providing self- security of the system
  • access control to the container by digital code or proximity card
  • early detection of smoke, air temperature increase, or fire inside the container
  • automatic activation of the fire extinguishing system if necessary
  • maintenance of working air temperature inside the container

PECULIARITIES

  • seamless switching to the power generation mode from the diesel generator
  • automatic startup of the diesel generator immediately after seamless switching
  • inverter that provides a clean sinusoidal waveform of the output voltage identical to the centralized power supply network
  • inverter’s high efficiency in combination with a set of battery packs ensures lasting operation time and reduces recharge time
  • remote monitoring of the system status via Ethernet
  • self-security system
  • extended temperature range that allows the system to be used in complex climatic conditions
  • fuel tank located inside the container preventing unauthorized fuel usage

SCOPE OF SUPPLY

Name

Quantity

Thermos container STVF.301179.002

1 pc.

Power cabinet STVF.426431.004

1 pc.

Insulated rack STVF.426479.048

1 pc.

Switchgear cabinet STVF.426479.053

1 pc.

Video camera SVK-855 STVF.426459.053

5 pcs.

Code panel STS-708 STVF.431295.035

1 pc.

Controller STS-423 STVF.426469.089

1 pc.

Diesel generator STVF.561343.001

1 pc.

Inverter MAP 15 kW (48V)

3 pc.

Optex LX-402 sensor

4 pcs.

IO-102-20 A2M detector

3 pcs.

Smoke-optical point fire detector IP 212-141

2 pcs.

IP 535-27 "IPR-Ex" manual fire detector

1 pc.

PC-186 power cable 1.8 m

1 pc.

Reversible 220V actuator KVU

2 pcs.

Buran-2.5-2C powder fire extinguishing module

1 pc.

Warning light "POWDER! DO NOT ENTER"

1 pc.

Convection heater CH 2000-2001

1 pc.

Sound warning device (two-tone siren) Ademco 702

1 pc.

Security-fire warning device Astra-10

1 pc.

LED emergency light LEDx30

2 pcs.

Industrial LED luminaire

2 pcs.

GX 12-200 DELTA rechargeable battery

10 pcs.

Spare parts set-O STVF.425973.109

1 set

Mounting parts set STVF.425951.042

1 set

Protective parts set STVF.425959.019

1 set

Operating documents list* STVF.565312.001 VE

1 copy

Operating guidelines** STVF.565312.001 RE

1 copy

Formulary STVF.565312.001FO

1 copy

* Full contents of the operational design documentation is in accordance with the list of operational documents

** The operating guidelines are supplied in a single copy when shipped with a batch of products or as part of a system. For single deliveries, the operating guidelines are supplied for each unit.

Operating guidelines are available at: http://stilsoft.ru

DESCRIPTION OF SYSTEM PARTS

  • thermos container is designed to accommodate the system's components and equipped with hermetically closing slide doors
  • diesel generator provides power to consumers with a variable three-phase current of 400 V and a frequency of 50 Hz
  • inverter with a set of battery packs provides uninterrupted and/or autonomous power supply to equipment operating at 220/230 V (or 380/400 V for a three-phase system)
  • STS-423 controller provides climate control inside the container, access control, fire protection, security, and storage of video archives
  • STS-708 code panel provides authorized access to the container by code or proximity card
  • SVK-855 cameras in a vandal-resistant case support the "day/night" mode, equipped with mechanical IR filters and built-in IR illumination, and serve to ensure the system's self-security
  • Optex LX-402 detector is designed to protect the system from unauthorized intrusion by detecting potential intruders approaching the container
  • BURAN-2.5-2S powder fire extinguishing module provides localization and extinguishing of fire in the container

RELIABILITY AND WARRANTY

  • System warranty period - 10 years
  • Battery pack warranty period - 2 years
  • Designated system operation period is 10 years

Parameter name

Value

Main generator power, kW/kVA (minimum)

30/37.5

Backup generator power, kW/kVA (minimum)

33/41.2

Frequency, Hz

50

Input/output voltage, V

400

Current type

AC three-phase

Autonomous operation time at 100% power, h (minimum)

48

Resource before major repair, h (minimum)

25000

Fuel type

Diesel

Fuel consumption, l/h

- at 75% load

- at 100% load


6.9

8.3

Total fuel tank capacity, l (minimum)

450

Generator startup time, min (maximum)

10

"Grid-Battery" transition time, ms (minimum)

20

"Battery-Grid" transition time, ms (minimum)

2

System operating time on fully charged batteries at maximum load of 30 kW, min (minimum)

20

Total capacity of rechargeable batteries, Ah

1600

Rated DC voltage on battery bus, V

48, 12

Number of batteries, pcs

8

Number of batteries to start diesel generator, pcs

2

Rated voltage of batteries for diesel generator, V

12

Battery type

Gel

Power supply delivery time

Linear-interactive

Lubrication system volume, l

12

Oil consumption at 100% load, l/h

0.02

Oil type

M-5Z/10G1

Short-circuit protection

Yes

Overload protection

Yes

Overheat protection

Yes

Interference filtration

Yes (partial)

Protection against high voltage pulses

Yes

Automatic fire suppression system

Yes

Video surveillance system

Yes

Manual control system

Yes

Security system

Yes

Access control system

Yes

Average service life, not less than, years

10

Range of operating temperatures, °C

from -60 to +60

Dimensions, mm

3500x2200x 2300

Weight with empty fuel tank and without batteries, kg (maximum)

3000

STILSOFT
Russian developer and manufacturer
of complex security systems
© 2023 "Stilsoft".
All rights reserved.
- Terms of use
- Trademarks
Headquarters in Stavropol city
Vasilkovaya street 29
Tel: +7 (8652) 52-44-44,
52-88-88, +7 (495) 663-71-75
E-mail: info@stilsoft.ru
Moscow office
Leninskaya Sloboda street 19
Tel: +7 (495) 663-71-75
E-mail: msk@stilsoft.ru
Moscow office
Leninskaya Sloboda street 19
Tel: +7 (495) 663-71-75
E-mail: msk@stilsoft.ru
St-Petersburg office
Obvodny Canal Embankment 14
Business Center "Technopark", office 245
Tel: +7 (812) 318-48-52
E-mail: spb@stilsoft.ru
St-Petersburg office
Obvodny Canal Embankment 14
Business Center "Technopark", office 245
Tel: +7 (812) 318-48-52
E-mail: spb@stilsoft.ru