PURPOSE
STS-107 dual-position radio wave security sensor is designed to detect intrusion into a secured facility and trigger an alarm message.
FIELDS OF APPLICATION
- integrated facility security systems
- perimeter and extended lines security systems
- stand-alone security alarm solution
VERSION
- the sensor consists of a receiver and a transmitter in sealed plastic casing
- receiver and transmitter are equipped with universal mounting brackets enabling their installation on Ø40 mm poles (via metal clamps) as well as on flat surfaces (via screws or bolts)
- bracket design enables rotation of receiver and transmitter casings at ±10° angle
FEATURES
- detecting an object crossing a secured line and triggering an alarm
- generating an ellipsoidal volumetric detection zone of 5 to 300 m in length
PECULIARITIES
- small width of the exclusion zone - an area free of vegetation, foreign objects and people which might interfere with the sensor's operability
- detection zone width depends on the distance between the receiver and the transmitter and peaks at the maximum range
- the horizontal distance from the axis of the detection zone to the boundaries of the exclusion
zone is: - at least 1.5 m for the 50-100 m section,
- at least 2.5 m for a 100-200 m section,
- at least 3 m for 200-300 m section
SCOPE OF SUPPLY
Name |
Quantity |
STS-107 security sensor, including: |
|
- receiver |
1 pc. |
- transmitter |
1 pc. |
Passport |
1 copy |
Spare parts-O set, including: |
1 set |
- self-tapping screw 2,9x6,5 DIN 7971 A2 |
4 pcs. |
- sealing fixture PG-7 |
1 pc. |
- Ziplock bag |
1 pc. |
Mounting set, including: Assembly parts kit: |
1 set |
- self-tapping screw 6,3x16 DIN 7504-K, stainless steel |
4 pcs. |
- Ziplock bag |
1 pc. |
Pack type 5 STVF.305646.007 |
1 pc. |
Operating guidelines* |
– |
* The operating guidelines are supplied in a single copy when shipped with a batch of products or as part of a system. For single deliveries, the operating guidelines are supplied for each unit. |
RELIABILITY AND WARRANTY
- Warranty operation period - 2 years.
- Assigned operation period - 10 years.
Parameter name |
Value |
Length of detection zone, m |
5 to 300 |
Detectable intruder movement speed in a standing or crouching position, m/s |
0,1 to 10,0 |
Operating frequency, MHz |
24000-24250 |
Remote control signal parameters: - pulse voltage, V - pulse duration, s (minimum) |
from 5 to 30 0,5 |
Detection zone width at equidistant interval from the units, at maximum range, m (maximum) |
3 |
Detection zone height at equidistant interval from the units at maximum range, m (maximum) |
3 |
Length of the uncertain detection zone at a distance from the transmitter and receiver, m (maximum) |
2 |
Receiving signal strength reserve at maximum detection range, dB (minimum) |
6 |
DC power supply voltage, V |
from 10 to 36 |
Allowable amplitude of supply voltage ripple, V (maximum) |
0,03* |
Current consumption at 12V operating voltage, mA (maximum): - transmitter - receiver |
160 200 |
Standby time after power-up, s (maximum) |
45 |
Alarm recovery time, s (maximum) |
10 |
Parameters of the signal generated by the output contacts of the "Alarm Relay" and "Tamper Sensor Alarm Relay" circuits: - current, DC or AC, mA (maximum) - amplitude voltage, V, max. (maximum) |
120 30 |
Alarm duration, s (minimum) |
2 |
Detection probability (minimum) |
0,98 |
Mean time between false alarms, h (minimum) |
60000 |
Sensor communication interface |
RS-485 |
False operation time, h (minimum) |
1200 |
Sensor information capacity via loop |
3 |
Sensor Information capacity via RS-485 bus |
19 |
Operating temperature range, °С |
от -50 до +70 |
Overall dimensions of receiver and transmitter (with bracket), mm |
210х210х141 |
Sensor weight in packaging, kg (maximum) |
1,3 |
* A higher amplitude of supply voltage ripple can cause a performance decline. |