PURPOSE
STS-119 electronic vibration sensor is designed to detect an intruder attempting to enter the secured room through an opening fitted with a metal grating.
FIELDS OF APPLICATION
- as a stand-alone detection device
- as part of integrated facility security systems in combination with detection equipment of other operating principles
VERSION
- sensor is a metal hermetically sealed casing with a vibration detector controller inside
- sensor casing is equipped with LED indication of operating modes
- sensor design enables its installation on grids with 8-24 mm diameter bars
FEATURES
- metal grating integrity and vibration monitoring
- sensor housing tampering detection
- transmission of malfunction notification via RS-485 interface and relays
- option to reset the settings to the default
PECULIARITIES
- works together with monitoring and control devices detecting changes in signal loop resistance value
SCOPE OF SUPPLY
Name |
Quantity |
STS-119 Security sensor |
1 pс. |
Mounting set STVF.425951.049, including: |
1 set |
- Washer 4 65G 016 GOST 6402-70 |
4 pcs. |
- Screw B2.M4-6g x 35.58.016 GOST 17473-80 |
4 pcs. |
- Washer C. 4.01.10.016 GOST 11371-78 |
4 pcs. |
- Bracket STVF.741461.002 |
1 pc. |
Packaging |
1 pc. |
Passport |
1 pc. |
Operating guidelines* |
– |
* The operating guidelines are supplied in a single copy when shipped with a batch of products or as part of a system. For single deliveries, the operating guidelines are supplied for each unit Operating guidelines are available at: http://stilsoft.ru |
RELIABILITY AND WARRANTY
- Warranty operation period - 2 years.
- Assigned operation period - 10 years.
Parameter name |
Quantity |
Device address - possible entries |
0-255 (1 by default) |
Grating breakage detection probability (minimum) |
0,99 |
Standby restoration time, s (maximum) |
10 |
Sensor technical standby interval, s (maximum) |
30 |
Alarm notification on casing tampering |
Yes |
Notification duration, s |
from 1 to 10 |
Sensor detection capability adjustment in manual/automatic modes |
Yes |
Communication interface |
RS-485 |
RS-485 bus information value |
11 |
Loop information value |
5 |
Controllable mesh area, m² (minimum) |
2 |
Permissible mesh rod diameter, mm |
8-24 |
Relay parameters: - maximum voltage, V - maximum current, mA - resistance in open state, Ohm |
50 400 2 |
DC power supply voltage, V |
from 10 to 30 |
Power consumption, mW (maximum) |
76 |
Generating ALARM signal through output circuit contacts opening |
Yes |
Operating mode |
round-the-clock |
Operating temperature range, °С |
from -40 to +50 |
Overall dimensions (HxWxH), mm |
103×69×58 |
Weight, kg (maximum) |
0,4 |