PURPOSE
STS-125 Passive single-position optical-electronic security sensor is designed for intrusion detection in the secured area and generating an alarm message.
FIELDS OF APPLICATION
- standalone detection device
- additional detection tool to eliminate dead zones of sensors with other principles of operation
- as part of integrated security systems of the facility
VERSION
- the sensor is a plastic casing, dustproof, containing the board with electronic components
- sensitive element lens is placed on the front panel of the casing
- there is a bracket on the housing for fixing the sensor
- the casing is equipped with light indicators to control operability
FEATURES
- forming the scanning area from narrow alternating sensitive and inactive zones
- registering changes in the level of infrared radiation caused by objects' movement in the detection area and triggering an alarm message
- sensor sensitivity adjustment
- covert triggering option without light indication
PECULIARITIES
- 24/7 operation with correct temperature control
- remote control of sensor operability
- low probability of false alarms
SCOPE OF SUPPLY
Name |
Quantity |
STS-125 Security sensor |
1 pc. |
Mounting set STVF.425951.074, including: |
1 set |
- Ziplock bag |
1 pc. |
- Screw 4,2х51 |
3 pcs. |
Spare parts set-O, including: |
1 set |
- Ziplock bag |
1 pc. |
- Screw 4,2х51 |
3 pcs. |
Packaging type 1 |
1 pc. |
Passport |
1 copy |
Operating guidelines * |
– |
* The operating guidelines are supplied in a single copy when shipped with a batch of products or as part of a system. For single deliveries, the operating guidelines are supplied for each unit Operating guidelines are available at: http://stilsoft.ru |
RELIABILITY AND WARRANTY
- Warranty operation period - 2 years
- Assigned operation period - 10 years
Parameter name |
Value |
Maximum detection range at 90 °horizontal view angle, m (minimum) |
12 |
Intruder speed detection range, m/s |
from 0.3 to 3.0 |
Intruder detection probability (minimum) |
0.98 |
Technical readiness time, s (maximum) |
30 |
Standby restoring time after alarm triggering, s (maximum) |
10 |
Alarm duration, s |
2 |
Data output |
relay, RS-485 |
Sensor informativity via loop |
5 |
Sensor informativity via RS-485 bus |
8 |
Product interference immunity from AC-powered electrical lighting devices, lux (minimum) |
2000 |
Product interference immunity from the sun and DC-powered light sources, lux (minimum) |
30000 |
DC power voltage, V |
8-30 |
Current consumption in standby and ALARM mode, at nominal voltage (maximum) |
30 |
Alarm triggering upon tampering the casing |
Yes |
Sensor vertical/horizontal rotation, deg. (minimum) |
±15 / ±90 |
Mean time between false alarms, h (minimum) |
1200 |
Protection against solid bodies (dust) and water ingress |
IP 54 |
Operation mode |
Continuous |
Operating temperature range, °С |
-40 to +50 |
Overall dimensions with bracket, mm |
155x75x145 |
Weight, kg (maximum) |
0.5 |